ARGUS 26 - PRI / BRI & Analogue Installation tester / simulator

 

Overview

The ARGUS26 is the premium tester for PRI, BRI, and POTS accesses as well as for permanent circuits.
The hand held unit is compact and easy to use with intuitive menus, cursor keys and soft keys.

On a PRI or BRI circuit, it supports TE/NT simulation & monitoring and can save the data in its 16 MB of internal memory and decode it.
Just plug in the Argus 26 to automatically detect the ISDN line configuration and protocol including point to point / point to multipoint, ISDN services available and any active call diversion
Additionally, this tester offers an E1 bit error rate test (MegaBERT).
Test reports can be easily generated using the WINplus software included.
Bit Error Rate tests may be run during a call with adjustable good / bad threshold and injection of errors if required. All results are displayed on the back lit LCD in clear text.
The Argus 26 has optional U-interface and X.21 access.

 

Specifications

Interfaces
BRI interface (TE/NT mode)
PRI Interface (TE/NT mode)
U interface (TE mode)
POTS interface (TE mode)
Protocol Support
Automatic detection of access configuration and protocol: ETSI Euro-ISDN, ITR6, Cornet-T / N, QSIG (B.C), X25 (D+B). V5.1/V5.2 monitoring (up to 3 time slots /multiple E1 links).
Bit Error Rate Tests
(G821/G826) Extended self call or end to end BERT, two concurrent BERT on Bx and By, loop box for all or selected B channels, displays bit error count and remaining measuring time, manual injection of bit errors, measuring time: 1 min. - infinite, BERT with adjustable OK/Not OK bit error rate threshold and evaluation.
PRI MegaBERT
E1 bit error rate test on all B channels/time slots simulateously.
Telephony Functions
Call number memory for 10 numbers or keypad protocol commands.
Displays for incoming calls: calling and called party numbers, B-channel, ISDN service, type of number and numbering plan, display information elements, Subaddress and UUS-1 data.
Displays during call: AOC-D in currency or charging units, display information elements, DTMF data.
Displays at end of call: AOC-E in currency/charging units, clearing cause by number/text incl. location.
Selectable B-channel, en-bloc or overlap signalling.
Automatic Supplementary Service Test
CLIP, CLIR, COLP, COLR, HOLD, TP, CFU, CFB, CFNR, AOC D/E, DDI, SUB, CCBS, CCNR, ECT, 3 PTY, DDI, UUS, support of keypad protocol.
Automatic Service Test
Determines which ISDN services are available in send and receive direction.
Test of ISDN Leased Lines Telephone function and BERT.
Selectable B channel and two concurrent BERT.
Loopbox for all or selected B channels.
Layer 1 Tests
Measurement and evaluation of the phantom power feed and the L1 signal.
Display of Layer 1 Info S0-S4.
Automatic X.31 Test on BRI
'Packet Data in D channel' available?
Automatic detection of the TEI's activated in the frame handler.
Simulation of X.31 (D) terminal to X.25 network.
Analogue Functions
POTS (a/b) interface with DTMF and pulse dial mode.
POTS voltage measurement.
Automatic detection of POTS interface.
Display of charging information.
Adjustable DTMF signal level and interval lenght.
CLIP and other caller ID services.
High Z monitor with non-intrusive listen-to on POTS and U.
LEDs
5 LEDs to indicate status (ISDN Layers 1-2-3, PC trace, power supply).
Size/Weight H 230 mm, W 72 mm, D 30 mm/ 395g (without batteries)
Power Powered by the BRI, battery, accumulator or power supply
Optional Accessories
U Interface.
X.21
V.35
V5.x monitor.
Printer kit.
Headset

Features

  • PRI and BRI interfaces in TE/NT mode + D-channel passive monitoring
  • E1 bit error rate test (MegaBERT) with n x 64kBit/s
  • POTS interfaces in TE mode
  • Optional support for X.21 and U interfaces
  • 16 MB internal memory for D-channel data
  • Permanent circuit test (including the D-channel(s) on a BRI or E1-PRI access)
  • Test of n x 64 kBit/s
  • Support for private protocols
  • Intuitive menu and operation
  • Automatic test sequence (AutoTest) with results saved
  • Data transfer to a PC + optional remote control from a PC
  • Powered by the BRI access, battery, accumulator or plug-in power supply (can recharge the accumulators in the tester)
  • Flash-ROM technology for software updates via a PC
  • Bit error test with support for 2E23-1 bit patterns
  • Optional:
    • U-interfaces in TE mode
    • X.21 interface

BERT & MegaBERT...
The Argus 26 allows a standard bit error rate test (BERT) to be performed using one or two timeslots (concurrently) on a framed G.704 line. However, a new optional MegaBERT feature allows the user to test the full bandwidth by running a BERT using all 32 timeslots on an unframed G.703 line (2048kbps), or timeslots 1-31 on a framed G.704 line (1984kbps).

WINplus...
WINplus is included with each Argus 26 and enables the user to generate access acceptance reports which document the work performed and the faults that occurred.

WINanalyse...
WINanalyse is an optional software package for the Argus 26 which provides comprehensive ISDN D Channel protocol analysis including ASN1 content. The simple Windows user interface aids identification of hidden protocol errors making it a useful tool when installing or servicing an ISDN access.



Download Argus 26 brochure in pdf format

>>> Pricing